Product Specification
Model | XB-OTS-50D | XB-OTS-80D | XB-OTS-150D | XB-OTS-225D | XB-OTS-408D | XB-OTS-1000D |
---|---|---|---|---|---|---|
Internal size WHD(cm) |
36*40*35 |
40*50*40 |
50*60*50 |
60*75*50 |
80*85*60 |
100*100*100 |
External size WHD(cm) |
148*172*160 |
152*182*170 |
162*192*184 |
172*207*184 |
192*217*198 |
200*232*235 |
Temp Shock Range
(Test Area) |
A: -40℃~+150℃ B:-55℃~+150℃ C:-65℃~+150℃ | |||||
Heating Time
(Heat Storage Area) |
RT-200℃ about 35min | |||||
Cooling Time
(Cold Storage Area) |
RT-70℃ about 70min | |||||
Temperature Fluctuation | ≤±0.5℃ | |||||
Temp Uniformity | ≤2℃ | |||||
Temp Uniformity | ≤±2℃ | |||||
Temperature Overshoot | ≤±3℃ | |||||
Recovery Time |
High temperature exposure for 30 minutes | |||||
Low temperature exposure for 30 minutes | ||||||
Screen |
Using imported programmable touch-type LCD Chinese and English diagram display microcomputer integrated controller. | |||||
Running Mode | Program Mode, Fixed Value Setting Mode | |||||
Setting Mode | Touch Screen Mode Input, Chinese And English Menu | |||||
Program Capacity |
Number of editable programs: maximum 20 steps; maximum 1000 steps; loops: maximum 20 (maximum 999 steps per cycle); Fixed program: 10 programs; programs can be linked (link program serial number can be selected). | |||||
Setting Range |
Temperature: adjust according to the temperature operating range of the equipment (upper limit+5℃, lower limit-5℃) | |||||
Humidity: 0-100%RH; (if the equipment has humidity function) |
Controller Features of Thermal Shock Test Chamber
- TH-900C touch display screen
- Equipped with 127 programs
- Built-in super-large storage space
- Automatic brightness adjustment
- Parameter input
- Convenient for up to 36 different outputs
Characteristics of OTS Technik Thermal Shock Chamber
- Protection: The chamber is made of cold-rolled steel plate and cured with double-sided electrostatic epoxy powder spray at 180℃, providing maximum protection for the test chamber installed in factory and laboratory environments. Temperature waterway and electrical control system isolation design to ensure safe operation.
- Air tightness: The chamber is a SUS#304 brushed stainless steel plate, manufactured by argon protective welding process.Silica rubber seals and eccentric locking device effectively seal the door and test chamber.
- Flexible: Customers can adjust the sample holder height to use more space. The air treatment room and control cabinet are located at the back of the chamber.The lifting castor wheel is installed at the bottom of the test chamber to facilitate movement.