Altitude Simulation Chamber Specification
MODEL | XB-OTS-408M | XB-OTS-800M | XB-OTS-1000M |
---|---|---|---|
Inner size (W*H*D) | 80*85*60 | 100*100*80 | 100*100*100 |
Pressure range | 101kPa ~ 0.5kPa | ||
Temperature / Humidity range | -70℃ ~ 150℃ / 20% ~ 98%R.H. Optional | ||
Boost and Step-down time | Boost: ≤10.0kPa
Step-down time: Normal pressure ~ 10kPa ≤30min |
Altitude Test Chamber Features
- Temperature: -70 ~170ºC.
- Altitude: ground to 100,000 feet.
- External pressure type box body structure, stainless steel tank design.
- Rational air circulation system, scientific heating, and refrigerating system layout.
- Adopts international brand of imported parts for the cooling systems to improve operational reliability.
- High precision and stable performance with touch screen controller, friendly Man-Machine interface.
- Multiple layers of the safety device, easy for maintenance.
- Viewing windows and cable ports are available.
- Vacuum pump sized for climb/dive rate required by the application.
Altitude Testing Chamber Applications
- Aerospace
- Metal Parts
- Electronics
- Car Spare Parts
- Communication Equipment
- Battery