Product Specification
1. Overall dimensions of the instrument
|
510*380*415mm(W*D*H)
|
2. Test space
|
360mm×330mm×100mm(W*D*H)
Visualize the sample bin and observe the sample during the test |
3.Spot size
|
Φ0.1mm,Φ0.3mm,Φ0.7mm,Φ1.2mm,Φ2mm,Φ5mm,Φ7mm
|
4. Weight
|
35kg |
5. Working temperature
|
15-30℃ |
6. Working Relative humidity:
|
≤75% (non-condensing)
|
7. Test element range:
|
Elements in S-U
|
8. Function description
|
Can be applied to RoHS directive, halogen-free directive, WEEE directive, ore, alloy analysis; Pb (lead), Cd (cadmium), Hg
(mercury), total Cr (chromium) and halogen total Br (bromine) in electronic and electrical plastic products, Cl (chlorine) element control. |
9. Types of analysis samples
|
Solid, liquid, powder, paste, etc .;
|
10. Test range:
|
1ppm—99.99%
|
11. Measurement time
|
60-240s (software automatic adjustment)
|
12. Warranty period
|
Two-year warranty (14 months), including three core components: X-ray
Tube, detector, high voltage power supply. |
13. Detector
|
Amptek X-123, resolution 145eV, full set of original imported integrated (probe + digital pulse processor)
|
14. X-ray tube
|
The maximum power is 50W, the molybdenum target side window X-ray tube (Be), and the service life: is more than 20,000 hours.
|
15. High voltage power supply
|
Maximum power 50W (50kV, 2mA) (0 ~ 2mA continuously adjustable)
|
16. Input power supply
|
AC 220V±10%,50Hz
|
17. Maximum power
|
330W
|
18. Filter/collimator
|
6 kinds of composite filters; 6 kinds of collimators; automatic switching;
|
19. Camera
|
5 million pixels
|
20. Software algorithm
|
Empirical coefficient method, standard internal method, standard curve method, basic parameter method
|
22. Software operating system
|
Open analysis model function, triple-ray protection system (software, hard
Parts, labyrinth design), automatic warning system for opening test, self-protection for overvoltage Protection, self-recovery. Circuit hardware safety interlock, misoperation 0.1uS fast cut X-ray source |
23. Report format
|
WORD, PDF, EXCEL, and report formats can be set according to customer needs.
|
24. Sample shape:
|
Solid, liquid, powder, etc., not limited
|
25. Sample thickness:
|
Not limited
|
26. Test requirements (features)
|
1. Positionable test;
2. The test completion software automatically determines whether it is qualified or not and automatically exports the test report with product pictures and spectrum diagrams; 3. A spectrum of the test elements and a spectrum comparison function exists. |
27. Sample test diameter:
|
Φ0.1mm—Φ25mm optional
|
28. Analytical detection limitations:
|
1ppm
|
29.RoHS measurement accuracy:
|
The measurement accuracy deviation of samples around 1000ppm is ± 50ppm; around 100ppm is ± 10ppm; the maximum detection limits of
Cr, Hg, Pb, and Cd are ≤2ppm |
Gold Tester Machine Features
- The machine for gold testing has a USB download function with an RS232 interface. The curve of the software does not need a recorder.
- A vacuum glass observation window makes direct observation of the function more effective.
- The refrigerant servo control valve flow calculation. Save electricity by 30%, dormancy in flow time, and save more than 50% energy.
- Preventing electromagnetic interference by SGS certification controller. At least 32 digital soft paths match with The Times development and software upgrade function.
- Defrost cycle (800 cycles defrost time, defrosting guarantee within 2 hours each time, integration test reach 25% of the energy saving province electricity)
Applications
SPR1 is a high-performance energy-dispersive X-ray fluorescence spectrometer (EDXRF). Original light path systems, heat dissipation systems, control systems, and software algorithms make SPR1 surpass similar products regarding test precision, accuracy, and ease of operation. Its excellent performance is widely used in RoHS / HF detection, heavy metal detection, alloy composition, precious metal detection, coating test, soil composition, mineral composition, and other fields users praise.