{"id":5723,"date":"2026-07-08T14:42:23","date_gmt":"2026-07-08T06:42:23","guid":{"rendered":"https:\/\/ots-testequipment.net\/?page_id=5723"},"modified":"2026-07-08T16:36:08","modified_gmt":"2026-07-08T08:36:08","slug":"norme-astm-b117","status":"publish","type":"page","link":"https:\/\/ots-testequipment.net\/fr\/design-standard\/astm-b117-standard\/","title":{"rendered":"Norme ASTM B117"},"content":{"rendered":"<section class=\"section\" id=\"section_1195155844\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n<div class=\"row\"  id=\"row-1043155826\">\n\n\t<div id=\"col-1255154466\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h1>Norme ASTM B117 relative au fonctionnement des appareils d'essai au brouillard salin<\/h1>\n<p>La norme ASTM B117 est une norme relative aux essais au brouillard salin (corrosion par brouillard salin) \u00e9labor\u00e9e par l'ASTM International. Il s'agit \u00e9galement de l'une des normes d'essais de corrosion les plus largement utilis\u00e9es \u00e0 l'\u00e9chelle mondiale. Cette norme d\u00e9finit les m\u00e9thodes op\u00e9rationnelles et les conditions d'essai de base pour les essais au brouillard salin. Les utilisateurs testent la r\u00e9sistance \u00e0 la corrosion des mat\u00e9riaux m\u00e9talliques, des rev\u00eatements et des traitements de surface dans un environnement contr\u00f4l\u00e9, conform\u00e9ment \u00e0 cette norme.<\/p>\n<p>La norme ASTM B117 d\u00e9finit principalement les exigences relatives \u00e0 la concentration de la solution saline, \u00e0 la temp\u00e9rature de la chambre d'essai, au pH, au d\u00e9bit de pulv\u00e9risation et aux param\u00e8tres associ\u00e9s. La dur\u00e9e pr\u00e9cise de l'essai et les crit\u00e8res d'\u00e9valuation reposent g\u00e9n\u00e9ralement sur les normes applicables au produit, les sp\u00e9cifications du secteur ou les exigences techniques du client. Si vous devez r\u00e9aliser des essais au brouillard salin conformes aux exigences de la norme ASTM B117, vous pouvez choisir le <span style=\"color: #0000ff;\"><strong><a style=\"color: #0000ff;\" href=\"https:\/\/ots-testequipment.net\/fr\/produit\/chambre-dessai-de-pulverisation-saly-de-precision\/\" target=\"_blank\" rel=\"noopener\">Chambre d'essai au brouillard salin OTS Technik.<\/a><\/strong><\/span><\/p>\n<a href=\"#is-pop\" class=\"button primary\" >\n\t\t<span>Demander un devis<\/span>\n\t<\/a>\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\n\t\t\n<style>\n#section_1195155844 {\n  padding-top: 30px;\n  padding-bottom: 30px;\n}\n<\/style>\n\t<\/section>\n\t\n\n\t<section class=\"section\" id=\"section_427952064\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n<div class=\"row align-middle\"  id=\"row-1108407376\">\n\n\t<div id=\"col-607391065\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h2>Champ d'application de la norme ASTM B117<\/h2>\n<p>La norme ASTM B117 est principalement utilis\u00e9e pour \u00e9valuer la r\u00e9sistance \u00e0 la corrosion des mat\u00e9riaux et produits suivants :<\/p>\n<ul>\n<li>Mat\u00e9riaux m\u00e9talliques<\/li>\n<li>Pi\u00e8ces \u00e9lectroplaqu\u00e9es et galvanis\u00e9es<\/li>\n<li>Rev\u00eatements organiques tels que la peinture et les rev\u00eatements en poudre<\/li>\n<li>Produits anodis\u00e9s et autres produits ayant subi un traitement de surface<\/li>\n<li>\u00c9l\u00e9ments de fixation, pi\u00e8ces automobiles, composants \u00e9lectroniques et articles de quincaillerie<\/li>\n<\/ul>\n<p><strong>Remarque : la norme ASTM B117 ne pr\u00e9cise ni les crit\u00e8res d'acceptation ni la dur\u00e9e des essais pour ces produits.<\/strong> Ces \u00e9l\u00e9ments doivent \u00eatre d\u00e9termin\u00e9s en fonction des normes applicables aux produits, des sp\u00e9cifications du secteur ou des exigences des clients.<\/p>\n<a href=\"#is-pop\" class=\"button primary\" >\n\t\t<span>Demander un devis<\/span>\n\t<\/a>\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1919722657\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1856863914\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/ots-testequipment.net\/wp-content\/uploads\/2023\/03\/Automotive-Salt-Fog-Chamber.webp\" class=\"attachment-original size-original\" alt=\"Automobile-Chambre de brouillard sal\u00e9\" srcset=\"https:\/\/ots-testequipment.net\/wp-content\/uploads\/2023\/03\/Automotive-Salt-Fog-Chamber.webp 1000w, https:\/\/ots-testequipment.net\/wp-content\/uploads\/2023\/03\/Automotive-Salt-Fog-Chamber-300x300.webp 300w, https:\/\/ots-testequipment.net\/wp-content\/uploads\/2023\/03\/Automotive-Salt-Fog-Chamber-80x80.webp 80w, https:\/\/ots-testequipment.net\/wp-content\/uploads\/2023\/03\/Automotive-Salt-Fog-Chamber-768x768.webp 768w, https:\/\/ots-testequipment.net\/wp-content\/uploads\/2023\/03\/Automotive-Salt-Fog-Chamber-12x12.webp 12w, https:\/\/ots-testequipment.net\/wp-content\/uploads\/2023\/03\/Automotive-Salt-Fog-Chamber-500x500.webp 500w, https:\/\/ots-testequipment.net\/wp-content\/uploads\/2023\/03\/Automotive-Salt-Fog-Chamber-100x100.webp 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1856863914 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\n\t\t\n<style>\n#section_427952064 {\n  padding-top: 30px;\n  padding-bottom: 30px;\n}\n<\/style>\n\t<\/section>\n\t\n\n\t<section class=\"section\" id=\"section_492288588\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n<div class=\"row\"  id=\"row-1122381120\">\n\n\t<div id=\"col-1924232801\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h2>Conditions d'essai selon la norme ASTM B117<\/h2>\n<table>\n<thead>\n<tr>\n<th>Param\u00e8tres<\/th>\n<th>Exigence<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Solution saline<\/td>\n<td>5% Chlorure de sodium<\/td>\n<\/tr>\n<tr>\n<td>Temp\u00e9rature ambiante<\/td>\n<td>35 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>pH<\/td>\n<td>6,5\u20137,2<\/td>\n<\/tr>\n<tr>\n<td>Collection Spray<\/td>\n<td>1 \u00e0 2 ml\/80 cm\u00b2\/h<\/td>\n<\/tr>\n<tr>\n<td>Type de pulv\u00e9risation<\/td>\n<td>Brouillard continu<\/td>\n<\/tr>\n<tr>\n<td>Air Supply<\/td>\n<td>Propre, satur\u00e9<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<a href=\"#is-pop\" class=\"button primary\" >\n\t\t<span>Demander un devis<\/span>\n\t<\/a>\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\n\t\t\n<style>\n#section_492288588 {\n  padding-top: 30px;\n  padding-bottom: 30px;\n}\n<\/style>\n\t<\/section>\n\t\n\n\t<section class=\"section\" id=\"section_1772244934\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n<div class=\"row\"  id=\"row-2107492061\">\n\n\t<div id=\"col-977754173\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h2 data-pm-slice=\"1 1 &#091;&#093;\">Proc\u00e9dure d'essai ASTM B117<\/h2>\n<h3><strong>1. Pr\u00e9paration des \u00e9chantillons<\/strong><\/h3>\n<p>Nettoyez et pr\u00e9traitez l'\u00e9chantillon afin d'\u00e9liminer toute trace d'huile, de poussi\u00e8re ou d'autres contaminants susceptibles d'influencer les r\u00e9sultats des essais.<\/p>\n<h3><strong>2. Pr\u00e9paration d'une solution saline<\/strong><\/h3>\n<p>Pr\u00e9parez la solution saline conform\u00e9ment \u00e0 la norme ASTM B117. Ajustez le pH pour qu'il se situe dans la plage sp\u00e9cifi\u00e9e.<\/p>\n<h3>3. Configuration de la chambre<\/h3>\n<p>Placez l'\u00e9chantillon \u00e0 l'int\u00e9rieur de la chambre d'essai et r\u00e9glez la temp\u00e9rature, le volume de pulv\u00e9risation, la pression d'air et les autres param\u00e8tres d'essai afin de respecter les exigences de la norme ASTM B117.<\/p>\n<h3>4. Exposition continue au brouillard salin<\/h3>\n<p>L'\u00e9chantillon a \u00e9t\u00e9 expos\u00e9 \u00e0 un environnement de brouillard salin en continu. La dur\u00e9e de l'essai doit \u00eatre d\u00e9termin\u00e9e en fonction des normes applicables au produit ou des exigences du client.<\/p>\n<h3>5. Inspection p\u00e9riodique<\/h3>\n<p>Inspectez les \u00e9chantillons aux intervalles indiqu\u00e9s afin de d\u00e9tecter la pr\u00e9sence de rouille, de cloques, de d\u00e9collement ou de tout autre signe de corrosion. Consignez les r\u00e9sultats des essais.<\/p>\n<h3>6. \u00c9valuation finale<\/h3>\n<p>Une fois l'essai termin\u00e9, les \u00e9chantillons font l'objet d'un contr\u00f4le final et d'une \u00e9valuation, puis un rapport d'essai est \u00e9tabli.<\/p>\n<a href=\"#is-pop\" class=\"button primary\" >\n\t\t<span>Demander un devis<\/span>\n\t<\/a>\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\n\t\t\n<style>\n#section_1772244934 {\n  padding-top: 30px;\n  padding-bottom: 30px;\n}\n<\/style>\n\t<\/section>\n\t\n\n\t<section class=\"section\" id=\"section_390631799\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n<div class=\"row align-middle\"  id=\"row-890539874\">\n\n\t<div id=\"col-1041816929\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h2>Comment les r\u00e9sultats des essais selon la norme ASTM B117 sont-ils \u00e9valu\u00e9s ?<\/h2>\n<p>\u00c0 l'issue de l'essai au brouillard salin, les utilisateurs v\u00e9rifient g\u00e9n\u00e9ralement l'\u00e9tat de corrosion de la surface de l'\u00e9chantillon, notamment :<\/p>\n<ul>\n<li><strong>Rouille rouge :<\/strong> Cela indique une corrosion du substrat, ce qui signifie g\u00e9n\u00e9ralement que le rev\u00eatement protecteur a cess\u00e9 d'\u00eatre efficace.<\/li>\n<li><strong>Rouille blanche<\/strong>: Il s'agit d'un ph\u00e9nom\u00e8ne courant de corrosion pr\u00e9coce que l'on observe sur les rev\u00eatements m\u00e9talliques, tels que les couches galvanis\u00e9es.<\/li>\n<li><strong>V\u00e9sicant<\/strong>: Des cloques apparaissent \u00e0 la surface du rev\u00eatement, ce qui est g\u00e9n\u00e9ralement li\u00e9 \u00e0 une d\u00e9faillance de celui-ci.<\/li>\n<li><strong>Corrosion par piq\u00fbres<\/strong>: Corrosion localis\u00e9e \u00e0 la surface du mat\u00e9riau qui entra\u00eene la formation de petits trous ou de cavit\u00e9s.<\/li>\n<li><strong>Corrosion par piq\u00fbres<\/strong>: Petits trous ou piq\u00fbres r\u00e9sultant d'une corrosion localis\u00e9e \u00e0 la surface d'un mat\u00e9riau.<\/li>\n<li><strong>Zone de corrosion<\/strong>: L'\u00e9tendue de la corrosion est \u00e9valu\u00e9e en fonction du pourcentage ou du degr\u00e9 de corrosion dans la zone touch\u00e9e.<\/li>\n<\/ul>\n<a href=\"#is-pop\" class=\"button primary\" >\n\t\t<span>Demander un devis<\/span>\n\t<\/a>\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-919275660\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_553193599\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img decoding=\"async\" width=\"1145\" height=\"750\" src=\"https:\/\/ots-testequipment.net\/wp-content\/uploads\/2026\/07\/How-are-ASTM-B117-test-results-evaluated.webp\" class=\"attachment-original size-original\" alt=\"Comment les r\u00e9sultats des essais selon la norme ASTM B117 sont-ils \u00e9valu\u00e9s ?\" srcset=\"https:\/\/ots-testequipment.net\/wp-content\/uploads\/2026\/07\/How-are-ASTM-B117-test-results-evaluated.webp 1145w, https:\/\/ots-testequipment.net\/wp-content\/uploads\/2026\/07\/How-are-ASTM-B117-test-results-evaluated-300x197.webp 300w, https:\/\/ots-testequipment.net\/wp-content\/uploads\/2026\/07\/How-are-ASTM-B117-test-results-evaluated-1030x675.webp 1030w, https:\/\/ots-testequipment.net\/wp-content\/uploads\/2026\/07\/How-are-ASTM-B117-test-results-evaluated-768x503.webp 768w, https:\/\/ots-testequipment.net\/wp-content\/uploads\/2026\/07\/How-are-ASTM-B117-test-results-evaluated-18x12.webp 18w, https:\/\/ots-testequipment.net\/wp-content\/uploads\/2026\/07\/How-are-ASTM-B117-test-results-evaluated-1000x655.webp 1000w\" sizes=\"(max-width: 1145px) 100vw, 1145px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_553193599 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\n\t\t\n<style>\n#section_390631799 {\n  padding-top: 30px;\n  padding-bottom: 30px;\n}\n<\/style>\n\t<\/section>\n\t\n\n\t<section class=\"section\" id=\"section_188401635\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n<div class=\"row\"  id=\"row-202217225\">\n\n\t<div id=\"col-1966322654\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h2>Dur\u00e9e de l'essai selon la norme ASTM B117<\/h2>\n<p>La norme ASTM B117 ne pr\u00e9cise pas en soi une dur\u00e9e d'essai fixe. La dur\u00e9e effective du cycle d'essai est g\u00e9n\u00e9ralement d\u00e9termin\u00e9e en fonction du type de produit, du mat\u00e9riau, de la m\u00e9thode de traitement de surface et des exigences du client ou du secteur.<\/p>\n<p>Les dur\u00e9es courantes des essais au brouillard salin sont notamment 24, 48, 96, 240 et 500 heures, voire plus. Plus la dur\u00e9e de l'essai est longue, plus la v\u00e9rification de la r\u00e9sistance \u00e0 la corrosion du produit doit g\u00e9n\u00e9ralement \u00eatre rigoureuse.<\/p>\n<p>Selon les applications \u2014 telles que les pi\u00e8ces automobiles, les \u00e9l\u00e9ments de fixation, les produits de rev\u00eatement et les \u00e9quipements maritimes \u2014, les dur\u00e9es d'essai peuvent varier.<\/p>\n<a href=\"#is-pop\" class=\"button primary\" >\n\t\t<span>Demander un devis<\/span>\n\t<\/a>\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\n\t\t\n<style>\n#section_188401635 {\n  padding-top: 30px;\n  padding-bottom: 30px;\n}\n<\/style>\n\t<\/section>\n\t\n\n\t<section class=\"section\" id=\"section_1162524826\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n<div class=\"row\"  id=\"row-1279865873\">\n\n\t<div id=\"col-1554187339\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h2>ASTM B117 et ISO 9227<\/h2>\n<table>\n<thead>\n<tr>\n<th>Article<\/th>\n<th>ASTM B117<\/th>\n<th>OIN 9227<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Organisme \u00e9metteur<\/td>\n<td>ASTM International<\/td>\n<td>Organisation internationale de normalisation (ISO)<\/td>\n<\/tr>\n<tr>\n<td>Champ d'application<\/td>\n<td>Largement utilis\u00e9 en Am\u00e9rique du Nord et dans des applications industrielles \u00e0 l'\u00e9chelle mondiale<\/td>\n<td>Largement utilis\u00e9 sur les march\u00e9s internationaux, notamment en Europe et dans d'autres r\u00e9gions<\/td>\n<\/tr>\n<tr>\n<td>Types de tests<\/td>\n<td>Essentiellement au brouillard salin neutre (NSS)<\/td>\n<td>Brouillard salin neutre (NSS), brouillard salin \u00e0 l'acide ac\u00e9tique (AASS), brouillard salin \u00e0 l'acide ac\u00e9tique acc\u00e9l\u00e9r\u00e9 par le cuivre (CASS)<\/td>\n<\/tr>\n<tr>\n<td>NSS<\/td>\n<td>Disponible<\/td>\n<td>Disponible<\/td>\n<\/tr>\n<tr>\n<td>AASS<\/td>\n<td>Non inclus<\/td>\n<td>Disponible<\/td>\n<\/tr>\n<tr>\n<td>CASS<\/td>\n<td>Non inclus<\/td>\n<td>Disponible<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<a href=\"#is-pop\" class=\"button primary\" >\n\t\t<span>Demander un devis<\/span>\n\t<\/a>\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\n\t\t\n<style>\n#section_1162524826 {\n  padding-top: 30px;\n  padding-bottom: 30px;\n}\n<\/style>\n\t<\/section>","protected":false},"excerpt":{"rendered":"","protected":false},"author":13,"featured_media":0,"parent":1434,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-blank.php","meta":{"footnotes":""},"class_list":["post-5723","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>ASTM B117 Standard for Operating Salt Spray (Fog) Apparatus - OTS TECHNIK<\/title>\n<meta name=\"description\" content=\"ASTM B117 specifies the requirements for salt spray (fog) corrosion testing. Learn the standard, test process, and choose OTS salt spray test chambers for accurate and repeatable corrosion testing.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/ots-testequipment.net\/fr\/norme-de-conception\/norme-astm-b117\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ASTM B117 Standard for Operating Salt Spray (Fog) Apparatus - OTS TECHNIK\" \/>\n<meta property=\"og:description\" content=\"ASTM B117 specifies the requirements for salt spray (fog) corrosion testing. Learn the standard, test process, and choose OTS salt spray test chambers for accurate and repeatable corrosion testing.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/ots-testequipment.net\/fr\/norme-de-conception\/norme-astm-b117\/\" \/>\n<meta property=\"og:site_name\" content=\"OTS TECHNIK\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-08T08:36:08+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/ots-testequipment.net\\\/design-standard\\\/astm-b117-standard\\\/\",\"url\":\"https:\\\/\\\/ots-testequipment.net\\\/design-standard\\\/astm-b117-standard\\\/\",\"name\":\"ASTM B117 Standard for Operating Salt Spray (Fog) Apparatus - OTS TECHNIK\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/ots-testequipment.net\\\/#website\"},\"datePublished\":\"2026-07-08T06:42:23+00:00\",\"dateModified\":\"2026-07-08T08:36:08+00:00\",\"description\":\"ASTM B117 specifies the requirements for salt spray (fog) corrosion testing. Learn the standard, test process, and choose OTS salt spray test chambers for accurate and repeatable corrosion testing.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/ots-testequipment.net\\\/design-standard\\\/astm-b117-standard\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/ots-testequipment.net\\\/design-standard\\\/astm-b117-standard\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/ots-testequipment.net\\\/design-standard\\\/astm-b117-standard\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/ots-testequipment.net\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Design Standard\",\"item\":\"https:\\\/\\\/ots-testequipment.net\\\/design-standard\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"ASTM B117 Standard\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/ots-testequipment.net\\\/#website\",\"url\":\"https:\\\/\\\/ots-testequipment.net\\\/\",\"name\":\"OTS TECHNIK\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/ots-testequipment.net\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Norme ASTM B117 relative aux appareils d'essai au brouillard salin (vapeur) - OTS TECHNIK","description":"La norme ASTM B117 d\u00e9finit les exigences relatives aux essais de corrosion par brouillard salin. D\u00e9couvrez cette norme et le processus d'essai, puis optez pour les chambres d'essai au brouillard salin OTS afin de r\u00e9aliser des essais de corrosion pr\u00e9cis et reproductibles.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/ots-testequipment.net\/fr\/norme-de-conception\/norme-astm-b117\/","og_locale":"fr_FR","og_type":"article","og_title":"ASTM B117 Standard for Operating Salt Spray (Fog) Apparatus - OTS TECHNIK","og_description":"ASTM B117 specifies the requirements for salt spray (fog) corrosion testing. Learn the standard, test process, and choose OTS salt spray test chambers for accurate and repeatable corrosion testing.","og_url":"https:\/\/ots-testequipment.net\/fr\/norme-de-conception\/norme-astm-b117\/","og_site_name":"OTS TECHNIK","article_modified_time":"2026-07-08T08:36:08+00:00","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/ots-testequipment.net\/design-standard\/astm-b117-standard\/","url":"https:\/\/ots-testequipment.net\/design-standard\/astm-b117-standard\/","name":"Norme ASTM B117 relative aux appareils d'essai au brouillard salin (vapeur) - OTS TECHNIK","isPartOf":{"@id":"https:\/\/ots-testequipment.net\/#website"},"datePublished":"2026-07-08T06:42:23+00:00","dateModified":"2026-07-08T08:36:08+00:00","description":"La norme ASTM B117 d\u00e9finit les exigences relatives aux essais de corrosion par brouillard salin. D\u00e9couvrez cette norme et le processus d'essai, puis optez pour les chambres d'essai au brouillard salin OTS afin de r\u00e9aliser des essais de corrosion pr\u00e9cis et reproductibles.","breadcrumb":{"@id":"https:\/\/ots-testequipment.net\/design-standard\/astm-b117-standard\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/ots-testequipment.net\/design-standard\/astm-b117-standard\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/ots-testequipment.net\/design-standard\/astm-b117-standard\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/ots-testequipment.net\/"},{"@type":"ListItem","position":2,"name":"Design Standard","item":"https:\/\/ots-testequipment.net\/design-standard\/"},{"@type":"ListItem","position":3,"name":"ASTM B117 Standard"}]},{"@type":"WebSite","@id":"https:\/\/ots-testequipment.net\/#website","url":"https:\/\/ots-testequipment.net\/","name":"OTS TECHNIQUE","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/ots-testequipment.net\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"}]}},"_links":{"self":[{"href":"https:\/\/ots-testequipment.net\/fr\/wp-json\/wp\/v2\/pages\/5723","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ots-testequipment.net\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/ots-testequipment.net\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/ots-testequipment.net\/fr\/wp-json\/wp\/v2\/users\/13"}],"replies":[{"embeddable":true,"href":"https:\/\/ots-testequipment.net\/fr\/wp-json\/wp\/v2\/comments?post=5723"}],"version-history":[{"count":11,"href":"https:\/\/ots-testequipment.net\/fr\/wp-json\/wp\/v2\/pages\/5723\/revisions"}],"predecessor-version":[{"id":5738,"href":"https:\/\/ots-testequipment.net\/fr\/wp-json\/wp\/v2\/pages\/5723\/revisions\/5738"}],"up":[{"embeddable":true,"href":"https:\/\/ots-testequipment.net\/fr\/wp-json\/wp\/v2\/pages\/1434"}],"wp:attachment":[{"href":"https:\/\/ots-testequipment.net\/fr\/wp-json\/wp\/v2\/media?parent=5723"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}